The simplex fiber optic cable are much stronger and tougher than common cables, which are designed to withstand crush, pressure, and rodent issues. They possess high flexibility and durability when used in harsh environments or limited space. When it comes to unarmored and armored fiber optic cables comparison, the distinctive difference lies in the outer protective layer. Precisely speaking, the armoring material doesn’t have to be metal, which can be fiber yarn, glass yarn, polyethylene, etc. The additional outer protective layer for optical cable makes the armored cable special, so the armored cables will be installed in locations that may expose to mechanical damages, while unarmored cables are normally used for control systems.
| Project | Technical indicators | |||||
| Cable Diameter(mm) | 1.6 | 1.8 | 2.0 | 2.4 | 2.8 | 3.0 |
| Cable weight(Kg/km) | 3.8 | 4.8 | 6.5 | 7.0 | 10.5 | 11.0 |
| Fiber Diameter(mm) | 0.25 | 0.5 | 0.5 | 0.5 | 0.5 | 0.9 |
| Armored tube Diameter(mm) | 0.6 | 0.9 | 0.9 | 0.9 | 0.9 | 1.5 |
| Fiber Type | SM9/125 MM50/125 MM62.5/125 OM3 OM4 | |||||
| Tensile Strength(N) | Long/Short Term:100/200 | |||||
| Crush (Max.N/100mm) | 2000 | |||||
| Min.Bending radius
(H=Cable Height) |
Long/Short Term:20xH/10xH | |||||
| Temperature(℃) | Storage /Operation:-20℃~+60℃ | |||||
| Parameter | Unit | 9/125
SMF-OS2 |
62.5/125
MMF-OM1 |
50/125
MF-OM2 |
50/125
MMF-OM3 |
50/125
MMF-OM4 |
| Attenuation | dB/Km | 1310nm≤0.35
1550nm≤0.22 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
| Dispersion | Ps/nm.km | 1285~1330nm≤3.5
1550nm≤18.0 |
– | – | – | – |
| Fiber Diameter | um | 9/125 um | 50/125 um | 50/125 um | 50/125 um | 50/125 um |
| Effective Modal Bandwidth | EMB | – | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 |
| Zero Dispersion Wavelength | Nm | 1300-1324 | – | – | – | – |
| Zero Dispersion Slope | Ps/nm.km | ≤0.095 | – | – | – | – |
| Fiber Cutoff Wavelength | Um | ≤1260 | – | – | – | – |
| Mode Field Diameter | Um | @1310nm-9.2±0.4
@1550nm-10.4±0.8 |
– | – | – | – |
| Mode Field Concentricity | Um | ≤0.8 | – | – | – | – |
| Cladding Diameter | Um | 125±1.0 | 125±2.0 | 125±2.0 | 125±2.0 | 125±2.0 |
| Cladding Non-circularity | % | ≤1.0 | ≤2.0 | ≤2.0 | ≤2.0 | ≤2.0 |
| Coating/Cladding | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Concentricity Error | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Coating Diameter | dB/Km | 245±10 | 245±10 | 245±10 | 245±10 | 245±10 |
Stainless steel wires enhance the crush resistance of the cable and anti-rodent
High strength aramid yarn,high performance outer sheath
Small bending radius,light weight,flexibility,and friendly installation.
Good mechanical and environmental performance.
Flame retardant outer sheath provide good safety.