The Rack mount PLC Fiber Optic Splitter adopts a standard rack mounted design, making it easy for users to install it on standard 19 inch or 23 inch racks. This design not only saves space, but also improves the stability and reliability of the equipment. This splitter provides multiple port configuration options, which can be flexibly selected according to actual needs. Meanwhile, its compact design allows for the installation of more ports in limited space, improving space utilization.
| Project | Technical indicators | |||||||||
| Product name | Rack-mount PLC Fiber Optic Splitter | |||||||||
| Parameter | Unit | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |||
| Fiber Type | / | G.657A,or customized | ||||||||
| Operating Wavelength | nm | 1260~1650 | ||||||||
| Insertion Loss | P | Max | dB | 4.0 | 7.0 | 10.4 | 13.5 | 16.8 | 20.5 | |
| S | Max | dB | 4.2 | 7.3 | 10.6 | 13.8 | 17.1 | 20.8 | ||
| PDL | Max | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | ||
| Loss Uniformity | Max | dB | 0.6 | 0.8 | 1.0 | 1.4 | 1.6 | 2.0 | ||
| Return Loss | Max | dB | 55(P Grade)/50(S Grade) | |||||||
| Directivity | Max | dB | 55 | |||||||
| Operating Temperature | ℃ | -40~+85 | ||||||||
| Storage Temperature | ℃ | -40~+85 | ||||||||
| Dimension(L x W x H) | mm | 482x200x45 | 482x200x89 | |||||||
| Remark:
The above parameters do not include connectors; If connectors are added,the insertion loss will increase 0.2dB each. |
||||||||||
| Parameter | Unit | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | |||
| Fiber Type | / | G.657A,or customized | ||||||||
| Operating Wavelength | nm | 1260~1650 | ||||||||
| Insertion Loss | P | Max | dB | 4.0 | 7.3 | 10.6 | 13.9 | 17.2 | 20.8 | |
| S | Max | dB | 4.2 | 7.5 | 11.0 | 14.5 | 17.5 | 21.0 | ||
| PDL | Max | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | ||
| Loss Uniformity | Max | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 | ||
| Return Loss | Max | dB | 55(P Grade)/50(S Grade) | |||||||
| Directivity | Max | dB | 55 | |||||||
| Operating Temperature | ℃ | -40~+85 | ||||||||
| Storage Temperature | ℃ | -40~+85 | ||||||||
| Dimension(L x W x H) | mm | 482x200x45 | 482x200x89 | |||||||
| Remark:
The above parameters do not include connectors; If connectors are added,the insertion loss will increase 0.2dB each. |
||||||||||
| Parameter | Unit | 9/125
SMF-OS2 |
62.5/125
MMF-OM1 |
50/125
MF-OM2 |
50/125
MMF-OM3 |
50/125
MMF-OM4 |
| Attenuation | dB/Km | 1310nm≤0.35
1550nm≤0.22 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
| Dispersion | Ps/nm.km | 1285~1330nm≤3.5
1550nm≤18.0 |
– | – | – | – |
| Fiber Diameter | um | 9/125 um | 50/125 um | 50/125 um | 50/125 um | 50/125 um |
| Effective Modal Bandwidth | EMB | – | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 |
| Zero Dispersion Wavelength | Nm | 1300-1324 | – | – | – | – |
| Zero Dispersion Slope | Ps/nm.km | ≤0.095 | – | – | – | – |
| Fiber Cutoff Wavelength | Um | ≤1260 | – | – | – | – |
| Mode Field Diameter | Um | @1310nm-9.2±0.4
@1550nm-10.4±0.8 |
– | – | – | – |
| Mode Field Concentricity | Um | ≤0.8 | – | – | – | – |
| Cladding Diameter | Um | 125±1.0 | 125±2.0 | 125±2.0 | 125±2.0 | 125±2.0 |
| Cladding Non-circularity | % | ≤1.0 | ≤2.0 | ≤2.0 | ≤2.0 | ≤2.0 |
| Coating/Cladding | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Concentricity Error | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Coating Diameter | dB/Km | 245±10 | 245±10 | 245±10 | 245±10 | 245±10 |
FTTX networks,PON networks;LAN networks,CATV systems.