The fibers are positioned in a loose tube made of high modulus plastic and filled with gel. Tubes (and fillers) are stranded around the non-metallic strength member to form the cable core.The cable core is filled with water blocking compound and PE inner jacket is extruded. Then the aramid yarn twist around the inner jacket to reinforce . Finally, PE outer jacket or AT outer jacket is completed.
| Project | Technical indicators (Span 100m) | ||||||||
| Counts | 2-30 | 32-36 | 38-60 | 62-72 | 74-96 | 98-120 | 122-144 | 146-216 | 218-288 |
| Max.fiber counts per tube | 6 | 6 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
| Unrts(Tubesor Fillers) | 6 | 6 | 6 | 6 | 8 | 10 | 12 | 18 | 24 |
| Cable Diameter ( mm) | 9.7 | 9.7 | 9.7 | 9.7 | 11.2 | 12.3 | 13.5 | 13.7 | 16.3 |
| Reference weight(Kg/km) | 74 | 75 | 75 | 75 | 100 | 120 | 143 | 142 | 195 |
| Fiber Type | G652D G655 G657 50/125 62.5/125 | ||||||||
| Tensile Strength(N) | Long/Short Term:1900/4800 | ||||||||
| Crush Resistance(N/100mm) | Long/Short Term :300/1000 | ||||||||
| Bending Radius(mm) | Static/Dynamic:10D/20D | ||||||||
| Temperature(℃) | Storage /Operation:-40℃*+70℃ | ||||||||
| Parameter | Unit | 9/125
SMF-OS2 |
62.5/125
MMF-OM1 |
50/125
MF-OM2 |
50/125
MMF-OM3 |
50/125
MMF-OM4 |
| Attenuation | dB/Km | 1310nm≤0.35
1550nm≤0.22 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
| Dispersion | Ps/nm.km | 1285~1330nm≤3.5
1550nm≤18.0 |
– | – | – | – |
| Fiber Diameter | um | 9/125 um | 50/125 um | 50/125 um | 50/125 um | 50/125 um |
| Effective Modal Bandwidth | EMB | – | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 |
| Zero Dispersion Wavelength | Nm | 1300-1324 | – | – | – | – |
| Zero Dispersion Slope | Ps/nm.km | ≤0.095 | – | – | – | – |
| Fiber Cutoff Wavelength | Um | ≤1260 | – | – | – | – |
| Mode Field Diameter | Um | @1310nm-9.2±0.4
@1550nm-10.4±0.8 |
– | – | – | – |
| Mode Field Concentricity | Um | ≤0.8 | – | – | – | – |
| Cladding Diameter | Um | 125±1.0 | 125±2.0 | 125±2.0 | 125±2.0 | 125±2.0 |
| Cladding Non-circularity | % | ≤1.0 | ≤2.0 | ≤2.0 | ≤2.0 | ≤2.0 |
| Coating/Cladding | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Concentricity Error | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Coating Diameter | dB/Km | 245±10 | 245±10 | 245±10 | 245±10 | 245±10 |
Self-supporting Aerial installation especially for electric field;
Structure can be customized for different spans.