Multi-Purpose Break-out Cable use simplex cable (Φ900μm tight buffer fiber, and aramid yarn as strength member units) as submit, a fiber reinforced plastic(FRP) locates in the center of core as a non- metallic strength member. The subunits are stranded around the cable core, and the cable completed with PVC or LSZH material jacket.
| Project | Technical indicators | ||||||||
| Fiber Count(F) | 4 | 6 | 8 | 12 | 24 | 36 | 48 | ||
| Cable Diameter(mm) | 7.5 | 8.5 | 10.0 | 12.5 | 15.5 | 17.5 | 20.0 | ||
| Cable weight(Kg/km) | 45 | 50 | 91 | 145 | 178 | 200 | 247 | ||
| Fiber Type | SM9/125 MM50/125 MM62.5/125 OM3 OM4 | ||||||||
| Tensile Strength(N) | Long/Short Term | ||||||||
| 200/400 | 250/600 | 300/800 | 400/1000 | 800/2200 | 1000/3000 | 1000/3000 | |||
| Crush Resistance(N/100mm) | Long/Short Term:300/1000 | ||||||||
| Bending Radius(mm) | Static/Dynamic:10D/20D | ||||||||
| Temperature(℃) | Storage /Operation:-20℃~+60℃ | ||||||||
| Parameter | Unit | 9/125
SMF-OS2 |
62.5/125
MMF-OM1 |
50/125
MF-OM2 |
50/125
MMF-OM3 |
50/125
MMF-OM4 |
| Attenuation | dB/Km | 1310nm≤0.35
1550nm≤0.22 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
| Dispersion | Ps/nm.km | 1285~1330nm≤3.5
1550nm≤18.0 |
– | – | – | – |
| Fiber Diameter | um | 9/125 um | 50/125 um | 50/125 um | 50/125 um | 50/125 um |
| Effective Modal Bandwidth | EMB | – | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 |
| Zero Dispersion Wavelength | Nm | 1300-1324 | – | – | – | – |
| Zero Dispersion Slope | Ps/nm.km | ≤0.095 | – | – | – | – |
| Fiber Cutoff Wavelength | Um | ≤1260 | – | – | – | – |
| Mode Field Diameter | Um | @1310nm-9.2±0.4
@1550nm-10.4±0.8 |
– | – | – | – |
| Mode Field Concentricity | Um | ≤0.8 | – | – | – | – |
| Cladding Diameter | Um | 125±1.0 | 125±2.0 | 125±2.0 | 125±2.0 | 125±2.0 |
| Cladding Non-circularity | % | ≤1.0 | ≤2.0 | ≤2.0 | ≤2.0 | ≤2.0 |
| Coating/Cladding | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Concentricity Error | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Coating Diameter | dB/Km | 245±10 | 245±10 | 245±10 | 245±10 | 245±10 |
Indoor any purpose cable distribution.
Backbone distribution cable in a building.