The LGX Box PLC Fiber Optic Splitter adopts an LGX box structure design, which is compact and easy to install. This design not only facilitates equipment maintenance and replacement, but also effectively protects the internal optical path and electronic components, ensuring stable operation of the equipment in various environments. The LGX Box PLC Fiber Optical Splitter achieves uniform distribution and efficient transmission of optical signals. Both multi wavelength and single wavelength signals can be efficiently and stably split through splitters, ensuring the quality of signal transmission.
| Project | Technical indicators | |||||||||||
| Product name | LGX Box PLC Fiber Optic Splitter | |||||||||||
| Parameter | Unit | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |||||
| Fiber Type | / | G.657A,or customized | ||||||||||
| Operating Wavelength | nm | 1260~1650 | ||||||||||
| Insertion Loss | P | Max | dB | 4.0 | 7.0 | 10.4 | 13.5 | 16.8 | 20.5 | |||
| S | Max | dB | 4.2 | 7.3 | 10.6 | 13.8 | 17.1 | 20.8 | ||||
| PDL | Max | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | ||||
| Loss Uniformity | Max | dB | 0.6 | 0.8 | 1.0 | 1.4 | 1.6 | 2.0 | ||||
| Return Loss | Max | dB | 55(P Grade)/50(S Grade) | |||||||||
| Directivity | Max | dB | 55 | |||||||||
| Operating Temperature | ℃ | -40~+85 | ||||||||||
| Storage Temperature | ℃ | -40~+85 | ||||||||||
| Dimension(L x W x H) | mm | 130x100x25 | 130x100x50 | 130x100x102 | 130x100x206 | |||||||
| Remark:
The above parameters do not include connectors; If connectors are added,the insertion loss will increase 0.2dB each. |
||||||||||||
| Parameter | Unit | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | |||||
| Fiber Type | / | G.657A,or customized | ||||||||||
| Operating Wavelength | nm | 1260~1650 | ||||||||||
| Insertion Loss | P | Max | dB | 4.0 | 7.3 | 10.6 | 13.9 | 17.2 | 20.8 | |||
| S | Max | dB | 4.2 | 7.5 | 11.0 | 14.5 | 17.5 | 21.0 | ||||
| PDL | Max | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | ||||
| Loss Uniformity | Max | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 | ||||
| Return Loss | Max | dB | 55(P Grade)/50(S Grade) | |||||||||
| Directivity | Max | dB | 55 | |||||||||
| Operating Temperature | ℃ | -40~+85 | ||||||||||
| Storage Temperature | ℃ | -40~+85 | ||||||||||
| Dimension(L x W x H) | mm | 130x100x25 | 130x100x50 | 130x100x102 | 130x100x206 | |||||||
| Remark:
The above parameters do not include connectors; If connectors are added,the insertion loss will increase 0.2dB each. |
||||||||||||
| Parameter | Unit | 9/125
SMF-OS2 |
62.5/125
MMF-OM1 |
50/125
MF-OM2 |
50/125
MMF-OM3 |
50/125
MMF-OM4 |
| Attenuation | dB/Km | 1310nm≤0.35
1550nm≤0.22 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
| Dispersion | Ps/nm.km | 1285~1330nm≤3.5
1550nm≤18.0 |
– | – | – | – |
| Fiber Diameter | um | 9/125 um | 50/125 um | 50/125 um | 50/125 um | 50/125 um |
| Effective Modal Bandwidth | EMB | – | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 |
| Zero Dispersion Wavelength | Nm | 1300-1324 | – | – | – | – |
| Zero Dispersion Slope | Ps/nm.km | ≤0.095 | – | – | – | – |
| Fiber Cutoff Wavelength | Um | ≤1260 | – | – | – | – |
| Mode Field Diameter | Um | @1310nm-9.2±0.4
@1550nm-10.4±0.8 |
– | – | – | – |
| Mode Field Concentricity | Um | ≤0.8 | – | – | – | – |
| Cladding Diameter | Um | 125±1.0 | 125±2.0 | 125±2.0 | 125±2.0 | 125±2.0 |
| Cladding Non-circularity | % | ≤1.0 | ≤2.0 | ≤2.0 | ≤2.0 | ≤2.0 |
| Coating/Cladding | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Concentricity Error | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Coating Diameter | dB/Km | 245±10 | 245±10 | 245±10 | 245±10 | 245±10 |
FTTX networks,PON networks;LAN networks,CATV systems.