The ABS Box PLC Fiber Optic Splitter uses high-quality ABS material to create its casing, which has excellent impact resistance, wear resistance, and weather resistance, ensuring stable operation of the equipment in various harsh environments. By utilizing PLC technology, precise distribution and transmission of optical signals have been achieved. Whether it is a multi wavelength or single wavelength signal, efficient and uniform splitting can be achieved through splitters, ensuring the stability and quality of signal transmission. It also supports multiple splitting ratios and port configurations, and can be flexibly selected according to actual needs.
| Project | Technical indicators | ||||||||||
| Product name | ABS Box PLC Fiber Optic Splitter | ||||||||||
| Parameter | Unit | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | ||||
| Fiber Type | / | G.657A,or customized | |||||||||
| Operating Wavelength | nm | 1260~1650 | |||||||||
| Insertion Loss | P | Max | dB | 4.0 | 7.0 | 10.4 | 13.5 | 16.8 | 20.5 | ||
| S | Max | dB | 4.2 | 7.3 | 10.6 | 13.8 | 17.1 | 20.8 | |||
| PDL | Max | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | |||
| Loss Uniformity | Max | dB | 0.6 | 0.8 | 1.0 | 1.4 | 1.6 | 2.0 | |||
| Return Loss | Max | dB | 55(P Grade)/50(S Grade) | ||||||||
| Directivity | Max | dB | 55 | ||||||||
| Operating Temperature | ℃ | -40~+85 | |||||||||
| Storage Temperature | ℃ | -40~+85 | |||||||||
| Dimension(L x W x H) | mm | 100x80x10 | 120x80x18 | 141x115x18 | |||||||
| Remark:
The above parameters do not include connectors; If connectors are added,the insertion loss will increase 0.2dB each. |
|||||||||||
| Parameter | Unit | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | ||||
| Fiber Type | / | G.657A,or customized | |||||||||
| Operating Wavelength | nm | 1260~1650 | |||||||||
| Insertion Loss | P | Max | dB | 4.0 | 7.3 | 10.6 | 13.9 | 17.2 | 20.8 | ||
| S | Max | dB | 4.2 | 7.5 | 11.0 | 14.5 | 17.5 | 21.0 | |||
| PDL | Max | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | |||
| Loss Uniformity | Max | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 | |||
| Return Loss | Max | dB | 55(P Grade)/50(S Grade) | ||||||||
| Directivity | Max | dB | 55 | ||||||||
| Operating Temperature | ℃ | -40~+85 | |||||||||
| Storage Temperature | ℃ | -40~+85 | |||||||||
| Dimension(L x W x H) | mm | 100x80x10 | 120x80x18 | 141x115x18 | |||||||
| Remark:
The above parameters do not include connectors; If connectors are added,the insertion loss will increase 0.2dB each. |
|||||||||||
| Parameter | Unit | 9/125
SMF-OS2 |
62.5/125
MMF-OM1 |
50/125
MF-OM2 |
50/125
MMF-OM3 |
50/125
MMF-OM4 |
| Attenuation | dB/Km | 1310nm≤0.35
1550nm≤0.22 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
850 nm≤3.0
1300 nm≤0.8 |
| Dispersion | Ps/nm.km | 1285~1330nm≤3.5
1550nm≤18.0 |
– | – | – | – |
| Fiber Diameter | um | 9/125 um | 50/125 um | 50/125 um | 50/125 um | 50/125 um |
| Effective Modal Bandwidth | EMB | – | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 | 850 nm≥200 |
| Zero Dispersion Wavelength | Nm | 1300-1324 | – | – | – | – |
| Zero Dispersion Slope | Ps/nm.km | ≤0.095 | – | – | – | – |
| Fiber Cutoff Wavelength | Um | ≤1260 | – | – | – | – |
| Mode Field Diameter | Um | @1310nm-9.2±0.4
@1550nm-10.4±0.8 |
– | – | – | – |
| Mode Field Concentricity | Um | ≤0.8 | – | – | – | – |
| Cladding Diameter | Um | 125±1.0 | 125±2.0 | 125±2.0 | 125±2.0 | 125±2.0 |
| Cladding Non-circularity | % | ≤1.0 | ≤2.0 | ≤2.0 | ≤2.0 | ≤2.0 |
| Coating/Cladding | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Concentricity Error | Um | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 | ≤12.5 |
| Coating Diameter | dB/Km | 245±10 | 245±10 | 245±10 | 245±10 | 245±10 |
FTTX networks,PON networks;LAN networks,CATV systems.